Sign In | Join Free | My xpandrally.com |
|
Place of Origin : SHANGHAI
Brand Name : IUXPOWER
Model Number : ALB-DR
Certification : CE
Price : T/T
Packaging Details : TO ME EMAIL
Delivery Time : TO ME EMAIL
Payment Terms : TO ME EMAIL
Supply Ability : TO ME EMAIL
MOQ : TO ME EMAIL
Packaging Detail: | standard packing or as requested. |
Delivery Detail: | 3 weeks after confirmation |
Load bank for Generators,UPS,Battery
1.Resistive
2.compact, easy for operation
3.professional design
4. factory directly
Resistive load bank
A resistive bank is used to test generators and prime movers. For every unit of load that is applied to the generator, the same unit of load is applied to the prime mover. In other words, the resistive load bank removes energy from all aspects of the generator system, providing a more complete test.
Portable, Permanent and Trailer mountings are available.
Sikes Portable resistive load banks ranges in size from 3KW to 1000KW, at 240 or 380 VAC, 3-phase or single phase, 50 or 60 Hz.
Sike permanent and trailer resistive load bank ranges in size from 2MW to 20MW, at 380 VAC, 3-phase, 50 or 60 Hz.
We can also customized to satisfy most load testing requirements at medium voltage(600V-11KV), high frequency(500Hz-600Hz).
Applications
Application
1.Factory testing of engine generator sets
2.To reduce "wet stacking" problems
3.Periodic exercising of stand-by engine generator sets
4.UPS system testing
5.Battery system testing
6.Ground power testing
7.Load optimization in prime power applications
Packaging Detail: | standard packaging or as requested |
Delivery Detail: | 2 Weeks |
dc load bank
1.customized battery DC load bank
2. for battery charging and discharging
3. factory directly, competitive price
DC Load Bank
DC automatic load bank is an instrument that can deeply discharge maintenance and capacity test to batteries. It is of high power density, no naked light, safe and long life. Voltage and current value can be displayed by LED.After setting parameter, it can achieve the capacity test of battery automatically constant-current /constant-resistance or the load capability test of DC power. Meanwhile, it is of multiple protection function and clocking/timing function.
Technical Parameters
Rated Amp | 1A~1000A |
Rated voltage | 12, 26, 28, 48, 52, 120, 130, 160, 270, 400 VDC or customized |
Cooling mode | Fans cooling or customized |
Working mode | load step control |
Load control accuracy | ±3%, or±5% |
Displaying meters | Mechanical or Digital displaying meter optional, display Volt, Amp, Hz, power factor and power |
Protections | over heating protection, cooling fans failure protection and over load protection with alarm |
Control mode | Manual control or Computor control |
Operating environment | Indoor or Outdoor. 1.Altitude: ≤1000m above sea level. 2.Ambient temp:-10°C~+40°C 3. Relative humidity: ≤80% ventilated environment without explosive or corrosive dust. |
Application
![]() |
Generators UPS Battery Variable Resistive Load bank Images |